Section 5: Commissioning
05/11 55 51209 Revision 2
5.7.2 Configuring Digital Inputs and Outputs
Under -[Digital I/O parameter], you can open the configuration menu for outputs and inputs:
Setup/Digital I/O parameter
Output 1 marker bit 1 X64=1
Output 2 marker bit 2 X65=1
Output 3 marker bit 3 X66=1
Input 1 on -no action-
Input 1 off -no action-
Input 2 on -no action-
Input 2 off -no action-
Input 3 on -no action-
Input 3 off -no action-
5.7.3 Configuring Outputs
Configure the required function for [Output 1] to [Output 3] by selecting a signal from the list; see
Chapter 5.7.1. The output goes to the corresponding state.
Example:
Setup/Digital I/O parameter
Output 1 below zero X35=1
Output 2 above Max X33=0
Output 3 center zero X36=1
Input 1 on -no action-
[Output 1] is true (active), when the weight value drops below zero (X35=1).
[Output 2] remains (active), as long as the weight is not above Max (X33=0).
[Output 3] is true (active), when the weight is zero +/- 1/4 d (X36=1).